Deskstar 34GXP
Jumper settings
Models: DPTA-373420, 372730, 372050, 371360
Jumper block locations

Jumper settings
Some systems may require you to use the 15 head logical architecture. This is because they translate a drive greater than 4 GB by multiplying the
head count by 16. The result (16 x 16 = 256) is interpreted as 0 heads with a 0 capacity and is an illegal head count. Selecting the 15 head logical
jumpers produces a legal translation (16 x 15 = 240). The translated cylinder count varies to achieve the drive's full capacity.

Capacity clip to 2GB/32GB with logical head 16
Jumpering 2GB/32GB capacity clip for a 34GB and higher drive will reduce the drive capacity to 33.8GB. Jumpering
2GB/32GB capacity clip for a drive with less than 34GB capacity will reduce the drive capacity to 2GB. This option can be used in situations where there is a
BIOS limitation and the drive is not recognized.
Disabling auto spin for logical head 16

Notes:
- 16 head logical architecture is enabled as the
shipping default. Master is set to on (i.e.
jumper on pins A-B and G-H). No other jumpers
are fitted.
- Auto Spin Disable, disables the drive from
automatically spinning up when power is applied.
- The clip capacity 2GB option clips the capacity
of the disk drive down to 2 GB. A 10.1GB drive
with this option set will appear as a 2GB drive.
- When CABLE SELECT is specified, AT interface
signal #28 CSEL determines the drive
address as follows:
- When CSEL is grounded or at a low level, the drive address is 0 (Device0).
- When CSEL is open or at a high level, the drive address is 1 (Device1).
|